Resultados 1 - 20 de 29
Filtrar
1.
Rapid Commun Mass Spectrom ; 38(11): e9742, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38587140

RESUMEN

RATIONALE: Atmospheric pressure interface multi-reflection time-of-flight mass spectrometry (API-MRTOF-MS) has the potential to be a rapid and high-resolution analytical tool for versatile applications in chemistry, biology, environmental science, and medicine. METHODS: The ions were reflected in a mass analyzer via electrostatic mirrors and folded flight path. Therefore, flight distances were significantly increased. The ion flight path of the API-MRTOF-MS was extended from meters to over 1 km, and the mass resolution was increased. Furthermore, the mass analysis could be completed at around 10 ms due to the rapid response of TOF-MS. RESULTS: A high-resolution API-MRTOF-MS approach is successfully developed in this study. The mass resolution could achieve 116 050 (full widths at half maximum [FWHM]) for Cs+ ions using an atmospheric pressure electrospray ionization within a total TOF of only 18 ms. An ion transmission efficiency of over 50% was achieved after 600 cycles. CONCLUSIONS: The analytical performance of the newly developed API-MRTOF-MS demonstrated that it is suitable for high resolution and rapid analysis in many fields.

2.
Anal Chem ; 95(28): 10769-10776, 2023 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-37343165

RESUMEN

Huanglongbing (HLB) is one of the most serious citrus diseases in the world. Rapid, onsite, and accurate field detection of HLB is a challenging task in analytical science for a long time. Herein, we have developed a novel HLB detection method that combines headspace solid phase microextraction with portable gas chromatography-mass spectrometry (PGC-MS) approach for onsite field detection of volatile metabolites of citrus leaves. Detectability and characteristics of HLB-affected metabolites from leaves were validated, and the important biomarkers were verified by authentic compounds. A machine learning approach based on random forest algorithm is established to model the volatile metabolites from healthy, symptomatic, and asymptomatic citrus leaves. In this work, a total of 147 citrus leaf samples were analyzed. Analytical performances of this newly developed method were investigated by in-field detection of various volatile metabolites. Results demonstrated limits of detection and quantification of 0.04-0.12 and 0.17-0.44 ng/mL for different metabolites, respectively. Linear calibration curves of various metabolites were established over a concentration dynamic range of at least three orders (R2 > 0.96). Good reproducibility was obtained for intraday (3.0-17.5%, n = 6) and interday precision (8.7-18.2%, n = 7). This new HLB field detection method provides a rapid detection with 6 min for each sample via a simple optimized procedure, including onsite sampling, PGC-MS analysis, and data process and provides a high accuracy (93.3%) for simultaneous identification of healthy, symptomatic, and asymptomatic trees. These data support the use of this new method for reliable field detection of HLB. Furthermore, metabolic pathways of HLB-affected metabolites were also proposed. Overall, our results not only provide a rapid and onsite field HLB detection method but also provide valuable information for understanding metabolic change of HLB infection.


Asunto(s)
Citrus , Rhizobiaceae , Reproducibilidad de los Resultados , Enfermedades de las Plantas , Espectrometría de Masas , Citrus/química , Citrus/metabolismo
3.
Food Res Int ; 169: 112819, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37254394

RESUMEN

To investigate the main aroma-active volatiles out from comprehensive chemical profile, we proposed an aroma correlation assisted volatilome coupled network analysis strategy and applied it to the study of Rosa roxburghii. Based on 475 detected volatiles with GC × GC-TOF/MS analysis, the volatilome was screened with both positive aroma activities and high contents to discover some aliphatic acids, alcohols, aldehydes and esters, terpenoids as well as some alkenes and ketones. Especially, a series of homologous C6- and C8- acids, alcohols, aldehydes, esters as well as some terpenoids like limonene take the predominant contributions to the aromas. Moreover, two aroma-active and aroma-contributing volatile groups including acid-aldehyde-alcohol-ester and terpenoid groups were clustered to integrally be responsible for the major aromas of R. roxburghii with network analysis. Additionally, the accumulation of C6- and C8-family homologous aliphatic volatiles was also elucidated with linoleic and linolenic acid derived pathways. This strategy is practical to investigate the main aroma-active volatiles based on volatilome.


Asunto(s)
Rosa , Compuestos Orgánicos Volátiles , Odorantes/análisis , Compuestos Orgánicos Volátiles/análisis , Terpenos , Etanol , Aldehídos/análisis , Ácidos , Ésteres/análisis
4.
Rapid Commun Mass Spectrom ; 37 Suppl 1: e9503, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36914281

RESUMEN

RATIONALE: Human breath analysis has been attracting increasing interest in the detection of abused drugs in forensic and clinical applications because of its noninvasive sampling and distinctive molecular information. Mass spectrometry (MS)-based approaches have been proven to be powerful tools for accurately analyzing exhaled abused drugs. The major advantages of MS-based approaches include high sensitivity, high specificity, and versatile couplings with various breath sampling methods. METHODS: Recent advances in the methodological development of MS analysis of exhaled abused drugs are discussed. Breath collection and sample pretreatment methods for MS analysis are also introduced. RESULTS: Recent advances in technical aspects of breath sampling methods are summarized, highlighting active and passive sampling. MS methods for detecting different exhaled abused drugs are reviewed, emphasizing their features, advantages, and limitations. The future trends and challenges in MS-based breath analysis of exhaled abused drugs are also discussed. CONCLUSIONS: The coupling of breath sampling methods with MS approaches has been proven to be a powerful tool for the detection of exhaled abused drugs, offering highly attractive results in forensic investigations. MS-based detection of exhaled abused drugs in exhaled breath is a relatively new field and is still in the early stages of methodological development. New MS technologies promise a substantial benefit for future forensic analysis.


Asunto(s)
Pruebas Respiratorias , Drogas Ilícitas , Humanos , Espectrometría de Masas/métodos , Pruebas Respiratorias/métodos , Sistema Respiratorio , Espiración
5.
Environ Sci Technol ; 56(23): 17100-17107, 2022 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-36395360

RESUMEN

Hazardous air pollutants can be unintentionally and intentionally released in many cases, such as industrial emissions, accidental events, and pesticide application. Under such events, the onsite operation is highly dependent on the molecular composition and spatial distribution of air pollutants in ambient air. However, it is usually difficult for people to reach hazardous and upper sites rapidly. In this work, we designed a new drone-based microextraction sampler array in which a solid-phase microextraction (SPME) fiber was mounted on drones for remote-control sampling at different spaces and was then coupled with a portable gas chromatography-mass spectrometry (PGC-MS) approach for quickly identifying hazardous air pollutants and their spatial distribution in ambient air within minutes. Acceptable analytical performances, including good sensitivity (detection limit at nanogram per liter level), reproducibility (relative standard deviation < 20%, n = 6), analytical speed (single sample within minutes), and excellent linear dynamic response (3 orders of magnitude) were obtained for direct measurement of air samples. The drone-SPME sampling mechanism of air pollutants involving an airflow adsorptive microextraction process was proposed. Overall, this drone-SPME sampling array can access hard-to-reach and dangerous environmental sites and provide air pollution distribution in different spaces, showing versatile potential applications in environmental analysis.


Asunto(s)
Contaminantes Atmosféricos , Microextracción en Fase Sólida , Humanos , Microextracción en Fase Sólida/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Contaminantes Atmosféricos/análisis , Reproducibilidad de los Resultados , Dispositivos Aéreos No Tripulados , Monitoreo del Ambiente/métodos
6.
Anal Bioanal Chem ; 414(20): 6115-6126, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35732744

RESUMEN

A novel home-made H2SO4-Nafion (HN) tube sampling system coupled to a line ion trap mass spectrometer (LTQ-MS) with a versatile ambient ionization source, hectowatt microwave plasma torch (HMPT), has manifested unique advantages for picking directly metal elements in aqueous samples and acquiring the fully characteristic MPT mass spectra of copper and zinc composite ions. Here, we report the development of a novel HN-HMPT-LTQ-MS for metal elements assay based on environmental water to analyze samples of Poyang Lake, China. Detailed multi-stage tandem mass spectra show that the general structural form of target ions is [M(NO3)x(H2O)y(OH)z]+ for the positive ion mode. Under the optimized conditions, the proposed method provided low limits of detection (LODs) of 0.23 µg.L-1 for 63Cu+ and 1.1 µg.L-1 for 66Zn+, with relative standard deviations (RSDs) of less than 12.7% by MPT-LTQ-MS. This new result has met the requirements of national standards (GB 5750.6-2006) and is only about one magnitude order larger than the LOD of ICP-MS method. A wide linear response range of about 4 orders of magnitude for the method with linear coefficients (R2) of 0.99709 - 0.99962 for copper and zinc tested was in accordance with that of ICP-MS. Except for the recovery of 79% for the third sample and 123.8% for the seventh sample, the present method also provided good recoveries (84 - 119.3%) in spiked 10 batches of drinking water samples. Furthermore, it is envisioned that the developed approach might build a powerful hectowatt-MPT-MS platform for food security detection, drug analysis, and origin traceability.


Asunto(s)
Cobre , Zinc , Cobre/análisis , Iones , Lagos , Metales/análisis , Espectrometría de Masas en Tándem , Agua/química , Zinc/análisis
7.
Anal Chim Acta ; 1164: 338510, 2021 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-33992222

RESUMEN

Solid phase microextraction (SPME) is one of the most powerful sample preparation techniques for analyte extraction and enrichment from complex matrices. SPME fibers are commonly used to extract analytes from collected samples. Following our recent work on development of in vivo SPME swab that integrates an SPME fiber and a medical swab (Anal Chim Acta, 2020, 1124, 71-77), the multiple SPME fibers inserted into a medical swab (multiple-SPME swab) is further developed to couple with different mass spectrometry (MS) approaches for multidimensional analysis of human saliva in this work. The new features of cotton ball and SPME fiber of multiple-SPME swab are investigated. Biomarker discovery and disease diagnosis using multiple-SPME swab are also demonstrated. The present study shows that direct coupling multiple-SPME swab with different MS-based approaches could be simple and versatile in vivo method to expand the classes of analytes extracted simultaneously from human saliva.


Asunto(s)
Saliva , Microextracción en Fase Sólida , Humanos , Espectrometría de Masas , Manejo de Especímenes
8.
Analyst ; 146(5): 1760-1771, 2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-33475106

RESUMEN

Inert metals are of much importance and play a key role in modern industrial manufacturing. The analytical techniques of inert metals remain challenging. In particular, the mass spectrometry of inert metal elements is yet to be further developed, which also limits the contemporary conceptual in situ analysis of inert metals. As the representative element, the mass spectral detection of palladium is critical and of far-reaching significance. Herein, we developed a mass spectrometry method, which can be used for the high-speed and in situ analysis of palladium, and even for other inert metals. Combining the line ion trap mass spectrometer with the versatile ambient ionization source, a novel kilowatt microwave plasma torch (MPT) can be used to obtain the fully characteristic MPT mass spectra of palladium. Detailed multistage tandem mass spectra show that the general form of target ions is [M(O2)x(NO)mNy(NO2)n]- for the negative ion mode and [M(H2O)x(NO2)y(N2)m]+ for the positive ion mode. Moreover, the formation and evolution of these palladium complex ions were reasonably derived based on the analysis of MPT background mass spectra. This mass spectrometric technique is also suitable for the determination of the palladium-containing solution in the sub-trace level. Semi-quantitative results showed that the detecting ability for palladium in the negative mode is better than that of the positive mode. Under the negative ion mode, the limit of detection (LOD) for m/z 259 were evaluated to be 0.5 µg L-1 under the optimized conditions of the negative mode, with the linear range of 1-100 µg·L-1 (R2 ≥ 0.9985) and the relative standard deviation (RSD, n = 11) being in the range of 1.20%-5.98% (refer to Table S3). Our experimental data showed that MPT-MS was a promising technique for providing another alternative in the on-site analysis of liquid samples and other intimate relevant fields, as the supplement of ICP-MS for the detection of inert metal elements. On the other hand, this work will also certainly promote the more broad applications of platinum-group elements (PGE) in modern science and industry.

9.
Chemosphere ; 264(Pt 1): 128430, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33002801

RESUMEN

Non-thermal plasma (NTP) has developed into an emerging end-of-pipe technology for treating volatile organic compounds (VOCs) present in unhygienic point source of air streams. In this work, NTP oxidation of low-concentration ethyl acetate was performed in a coaxial double dielectric barrier discharge reactor. The effects of initial ethyl acetate concentration, gas flow rate, and external electrode length on ethyl acetate degradation were systematically investigated as a function of discharge power. In addition, detailed real-time and online proton transfer reaction mass spectrometry analysis was used to identify the transient species formation and transition in the various NTP oxidation periods of ethyl acetate. Based on the analysis of organic by-products, the degradation mechanism was speculated and the major reaction channels were presented. This study would deepen the understanding of plasma degradation of VOCs and reveal the plasma-chemical mechanism.


Asunto(s)
Gases em Plasma , Compuestos Orgánicos Volátiles , Acetatos , Espectrometría de Masas
10.
J Mass Spectrom ; 56(4): e4588, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32633879

RESUMEN

Breath volatile biomarkers are capable of distinguishing patients with various cancers. However, high throughput analytical technology is a prerequisite to a large-cohort study intended to discover reliable breath biomarkers for cancer diagnosis. Single-photon ionization (SPI) is a universal ionization technology, and SPI-mass spectrometry (SPI-MS) shows a remarkable advantage in the comprehensive detection of volatile organic compounds (VOCs), in particular, nonpolar compounds. In this study, we have introduced SPI-MS coupled with on-line thermal desorption (TD-SPI-MS) to demonstrate nontarget analysis of breath VOCs for gastric cancer patients. The breath fingerprints of the gastric cancer patients were significantly distinct from that of the control group. Acetone, isoprene, 1,3-dioxolan-2-one, phenol, meta-xylene, 1,2,3-trimethylbenzene, and phenyl acetate showed higher relative peak intensities in the breath profiles of gastric cancer patients. A diagnostic prediction model was further developed by using a training set (121 samples) and validated with a test set (53 samples). The predication accuracy of the developed model was 96.2%, and the area under the curve (AUC) of the receiver operator characteristic curve (ROC) was 0.997, indicating a satisfactory prediction ability of the developed model. Thus, by taking gastric cancer as an example, we have shown that TD-SPI-MS will be a promising tool for high throughput analysis of breath samples to discover characteristic VOCs in patients with various cancers.


Asunto(s)
Biomarcadores de Tumor/análisis , Pruebas Respiratorias/métodos , Espectrometría de Masas/métodos , Neoplasias Gástricas/diagnóstico , Compuestos Orgánicos Volátiles/análisis , Acetatos/análisis , Acetona/análisis , Butadienos/análisis , Estudios de Cohortes , Dioxolanos/análisis , Espiración , Hemiterpenos/análisis , Humanos , Fenol/análisis , Fenoles/análisis , Curva ROC , Xilenos/análisis
11.
Sci Total Environ ; 754: 142182, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33254891

RESUMEN

Many field studies have investigated the formation mechanisms of organic aerosol (OA) based on bulk analysis, yet the source and formation process of individual organic particles may be quite different due to the diversity of chemical composition and mixing state in single particles. Here we present the observation results of chemical composition and mixing state of carbonaceous single particles at an urban site in Guangzhou. The carbonaceous particles accounted for 74.6% of the total detected single particles, and were grouped into four types including elemental carbon-aged (EC-aged), elemental and organic carbon (ECOC), organic carbon-rich (OC-rich) and secondary ions-rich (SEC) particles. The formation of EC-aged particles was closely associated with the absorption of organics onto fresh EC particles from primary sources, and the further enrichment of organics in EC-aged particles resulted in the production of ECOC particles. In the daytime OC-rich and SEC particles were mainly produced from the photochemical reactions, while in the nighttime their sharp increases were found along with the enrichment of nitrate and organic nitrogen fragments, suggesting the heterogeneous formation of nitrate and organic nitrogen in OC-rich and SEC particles. The production rates of carbonaceous particles were also investigated in an episodic event, and the EC-aged particles showed the highest production rate compared to the other carbonaceous particles both in the daytime and nighttime, suggesting a significant role of EC in the formation and aging process of carbonaceous particles. The results from this work have revealed different formation processes and production rates of carbonaceous particles due to their diversity in mixing state, providing further insights into the formation mechanisms of OA in field studies.

12.
Anal Methods ; 12(35): 4343-4350, 2020 09 17.
Artículo en Inglés | MEDLINE | ID: mdl-32844845

RESUMEN

Real-time monitoring of volatile organic compounds (VOCs) is critical for a better understanding of chemical processes in ambient air or making minute-by-minute decisions in emergency situations. Proton transfer reaction mass spectrometry (PTR-MS) is nowadays the most commonly used technique for real-time monitoring of VOCs while membrane single photon ionization mass spectrometry (MI-SPI-MS) is a promising MS technique for online detection of trace VOCs. Here, to evaluate the potential of MI-SPI-MS as a complementary tool to PTR-MS, a comprehensive comparison has been performed between MI-SPI-MS and PTR-MS. By using two sets of standard gas mixtures TO15 and PAMS, SPI-MS shows advantages in the detection of ≥C5 alkanes, aromatics and halogens; especially for aromatics, the LODs can reach the ppt level. PTR-MS has performed better in the detection of alkenes, ketones and aldehydes. For outdoor measurements, a number of VOCs have been detected while using MI-SPI-MS and PTR-MS in parallel. Consistent temporal variations have been observed for toluene, C8-aromatics and C9-aromatics by the two instruments, with a more sensitive response from the MI-SPI-MS. Thus by measuring both standard gas mixture and complex ambient air samples, we have successfully demonstrated that MI-SPI-MS will be a helpful tool to provide important complementary information on aromatics and alkanes in air, and proper application of MI-SPI-MS will benefit the real-time monitoring of trace VOCs in relative fields.

13.
Anal Chim Acta ; 1124: 71-77, 2020 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-32534677

RESUMEN

In vivo sampling and sensitive detection of environmental pollutants and drugs in human body play a crucial role in understanding human health. In this study, in vivo solid-phase microextraction (SPME) swab was fabricated using a SPME fiber and a medical cotton swab for noninvasive sampling and extraction of environmental pollutants and drugs in human oral cavity, nasal cavity and on skin surface. After sampling, SPME was coupled with nano-electrospray ionization mass spectrometry (nanoESI-MS) for desorption, ionization, and detection of the extracted analytes. As a result, limit of detection (LOD) and limit of quantification (LOQ) of nicotine in oral fluid were found to be 1.0 pg/mL (S/N ≥ 3) and 4.0 pg/mL (S/N ≥ 10), respectively. Linear dynamic signal responses of nicotine exhibited excellent linearity (R2 = 0.9996) in human oral fluid ranging from 0.1 to 50 ng/mL. The coefficient of variation (CV) values of SPME swab for five measurements from sample vials and human body were 5.1-6.7% and 22.7-32.6%, respectively. Rapid analysis of a single sample could be completed within 10 min. Overall, our results demonstrated that SPME swab-MS is a promising noninvasive method for enhanced detection of analytes in human body.


Asunto(s)
Contaminantes Ambientales/análisis , Boca/química , Nanotecnología , Piel/química , Microextracción en Fase Sólida , Cafeína/análisis , Cuerpo Humano , Humanos , Imidazoles/análisis , Nanotecnología/instrumentación , Nicotina/análisis , Microextracción en Fase Sólida/instrumentación , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Teobromina/análisis , Teofilina/análisis
14.
J Am Soc Mass Spectrom ; 31(2): 434-440, 2020 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-32031385

RESUMEN

A miniature reflectron time-of-flight mass spectrometer (TOF MS) with orthogonal extraction coupled with electron impact (EI) ionization source can be used to perform in situ gas composition analysis in a planetary environment. However, performances such as the mass resolution, sensitivity, limit of detection, mass range, and mass accuracy are often decreased because of miniaturization. Herein, a compact instrument for space applications has been developed, and its performance has been evaluated. The mass of the TOF MS is 13.4 kg, with dimensions of 300 mm × 200 mm × 200 mm, and the power consumption is 25 W. In this paper, the design of the ion source, mass analyzer, and detector is discussed in detail. The upper limit of the mass range is greater than 500 amu, and the best resolving power obtained so far on the miniature TOF MS is around 405 at full width half maximum (FWHM); other performance indexes of the instrument are also determined, where the worst case for mass stability is 0.49%, together with a mass accuracy of 0.12% and a sensitivity of 0.6 mV/ppm.

15.
Rapid Commun Mass Spectrom ; 34(9): e8701, 2020 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-31845394

RESUMEN

RATIONALE: Linear matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is widely used in analytical and biomedical applications. The use of delayed extraction increases the resolution, but the roughness of the matrix crystals and the misalignment of the target plate in the order of a few micrometers cause a substantial spread in the ion TOF values and a decrease in mass accuracy. METHODS: The method of mass spectra correction based on the correlation of matrix fragment peaks in MALDI mass spectra was used. Experiments were performed using the MALDI-TOF instrument CMI-1600. SIMION 8.1 and MATLAB were used for ion motion simulations. Data analysis was done using the home-built custom-developed software and MATLAB. RESULTS: It was shown that the peak position drift in the MALDI-TOF mass spectra depends linearly on the TOF in a wide mass range. While using the linear correction of the TOF scale, an increase in m/z accuracy of more than 10 times was achieved. The mass accuracy was limited by the resolution of the fast Analog-to-Digital Converter (ADC) used. CONCLUSIONS: It is expected that the proposed method will significantly increase the dynamic range, since it becomes possible to sum up corrected individual mass spectra without a significant loss of resolution. Timescale adjusting can be used for both linear TOF instruments and reflector systems of various configurations.

16.
Rapid Commun Mass Spectrom ; 33(24): 1877-1883, 2019 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-31429145

RESUMEN

RATIONALE: Herbal dietary supplements (HDSs) adulterated with undeclared synthetic drugs can lead to serious health problems METHODS: A fast-switching positive/negative high-voltage (+/- HV) was developed to apply on electrospray ionization mass spectrometry (ESI-MS) with porous tips for rapid screening of five antirheumatic drugs in antirheumatic HDSs. The fast-switching (switch-time: 100 ms) negative and positive ions were alternately generated to perform full-MS and tandem-MS analysis, providing an effective method for rapid detection of analytes in whichever mode of detection was most suitable (negative or positive ion mode). The use of different tips and solvents was also optimized in this work. RESULTS: The limits of detection of the five antirheumatic drugs were found to be less than 0.1 ng/g (S/N > 3). The reproducibility of the five drugs was measured to be 10.0-23.3% (n = 5). A single sample analysis could be completed within 1 min. Rapid screening of a total of 28 real HDS samples collected from the market was examined by the fast-switching HV substrate-tip ESI-MS method, and the screening result was further validated by conventional liquid chromatography/mass spectrometry. CONCLUSIONS: Overall, our results demonstrated that fast-switching HV substrate-tip ESI-MS is a rapid, reliable, and effective method for simultaneous screening of various analytes in complex samples.


Asunto(s)
Antirreumáticos/análisis , Contaminación de Medicamentos , Medicamentos Herbarios Chinos/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Suplementos Dietéticos/análisis , Contaminación de Medicamentos/estadística & datos numéricos , Sensibilidad y Especificidad
17.
Anal Chim Acta ; 1050: 105-112, 2019 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-30661577

RESUMEN

Electrospray ionization mass spectrometry (ESI-MS) is one of the most powerful ionization techniques for characterization of analytes in various areas. Polar solvents such as methanol, water and acetonitrile are commonly used for ESI-MS analysis, while nonpolar solvents such as hexane were usually considered as non-ESI-friendly solvents. Following our recent work on observation of ESI process from solid substrates using nonpolar solvents (Anal Chim Acta, 2018, 1004, 51-57), the analytical properties of ESI-MS with solid substrates and nonpolar solvents were further systematically investigated in this study. Compared to the uses of polar solvents, our results revealed that nonpolar solvents could serve as extractants for enhanced detection of low-polar analytes from complex samples, and could serve as refrigerants for rapid freezing of samples such as peptides, proteins and protein-ligand complexes. Furthermore, nonpolar solvents could be used for formation of ammonia-transition-metal acetylacetonates complexes under ambient conditions.


Asunto(s)
Compuestos Organometálicos/síntesis química , Péptidos/análisis , Proteínas/análisis , Solventes/química , Amoníaco/química , Hidroxibutiratos/química , Ligandos , Metales Pesados/química , Estructura Molecular , Compuestos Organometálicos/química , Pentanonas/química , Espectrometría de Masa por Ionización de Electrospray
18.
J Am Soc Mass Spectrom ; 29(10): 2105-2109, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30105739

RESUMEN

A specific delayed ion extraction (DIE) technique, which combines a standard rectangular extraction pulse with an exponential pulse, was introduced for a single particle mass spectrometry (SPMS) instrument, and it can focus ions in a wide mass range and results in a mass resolution improvement for the mass range of the studied ions. The experimental results indicate that the average mass resolution for positive ions is about 1000 when the mass-to-charge ratio (m/z) is greater than 70, and for negative ions, when the m/z is greater than 70, the average resolution can reach 2000. The highest mass resolutions achieved so far are 1260 for positive ions and 2400 for negative ions for SPMS, which are very beneficial for mass peak interpretation and chemical compound identification. The primary applications for atmospheric particle measurements show that the high mass resolution of SPMS with the DIE technique is very beneficial for the analysis of carbon and metallic element containing particles, and 39K+ with C3H3+ and 41K+ and C3H5+ in organic particles were successfully differentiated using SPMS. The results indicate that SPMS with DIE technique can significantly ease mass peak interpretation and improve the mass assignment ability during analysis. Furthermore, existing SPMS instruments can be improved by a facile retrofitting process to implement the DIE technique. Graphical Abstract The delayed ion extraction method shows a great mass resolution improvement for single particle mass spectrometry.

19.
J Am Soc Mass Spectrom ; 29(7): 1386-1393, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29713965

RESUMEN

Chemical mass shifts between isomeric ions of o-, m-, and p-xylene were measured using a digital linear ion trap, and the directions and values of the shifts were found to be correlated to the collision cross sections of the isomers. Both forward and reverse scans were used and the chemical shifts for each pair of isomers in scans of opposite directions were in opposite signs. Using different voltage settings (namely the voltage dividing ratio-VDR) of the ion trap allows adding high order field components in the quadrupole field and results in larger chemical mass shifts. The differential chemical mass shift which combined the shifts from forward and reverse scans doubled the amount of chemical shift, e.g., 0.077 Th between o- and p-xylene, enough for identification of the type of isomer without using an additional ion mobility spectrometer. The feature of equal and opposite chemical mass shifts also allowed to null out the chemical mass shift by calculating the mean m/z value between the two opposite scans and remove or reduce the mass error caused by chemical mass shift. Graphical Abstract ᅟ.